DATA ACQUISITION
GATEWAY & SERVER
AcuLink 810 is an intelligent data acquisition server and gateway designed to collect aggregated energy, water, gas, or other utility data from multiple meters and field sensors in a facility. Compatible with all Accuenergy meters and third-party devices, it stores data locally until it is ready to be distributed to remote servers or controllers via an IP-based network. The built-in web interface makes it simple to monitor critical energy data from all connected devices, promoting real-time decision making and management.
- Gateway supports multiple networks including Modbus, BACnet, SunSpec, Mbus, MQTT, SNMP for intercommunication between devices
- Post or push data using multiple formats for straightforward integration with existing software or control systems
- Browser accessible web interface facilitates quick, software-free setup and remote data access
- 8GB datalogger onboard memory rapidly logs data up to once per second
- Multi-protocol support for compatibility with industrial, data center, or other critical installations
- Dual Ethernet ports for simple, RSTP compliant network connectivity
- Wireless communications through WiFi plus optional AcuMesh support for wireless RS485 data collection
- TLS 1.2 compliance for enhanced cybersecurity in critical infrastructure deployments
- Auto-discovery of devices available for BACnet networks
- Support EPICS files to build BACnet device templates
AcuLink 810 Overview
What is a Data Acquisition Gateway and Server?
A data acquisition (DAQ) system serves as a central hub between interconnected devices designed to aggregate critical facility data such as power consumption or temperature readings. Using a variety of industrial protocols, it can poll downstream energy meters at regular intervals and post the data to the Cloud, or web servers for remote access to realtime energy & facility management.
Benefits of a Data Acquisition Gateway
- Provides a communication pathway between master and slave devices operating with different protocols
- Bridges the gap between legacy devices and updated hardware
- Drives interoperability between devices, automation systems, and other building services
- Entire legacy systems do not need to be replaced immediately, extending the lifespan existing devices
- Realized savings from extending the lifespan of existing devices
- Able to mix and test different devices for better cost-savings
AcuLink 810 Main Features
DATA ACQUISITION (DAQ)
AcuLink 810 can gather data from any Accuenergy or third-party meters, sensors, or other field devices for a seamless network under one centralize hub and supports a large number of standard protocols.
Key Specifications:
- Multiple connection methods including Ethernet, WiFi, RS485, & wireless Mesh
- Support for standard industrial protocols: Modbus-RTU, Modbus TCP/IP, BACnet MT/TP, BACnet-IP, MBus, Virtual Meters and more
- Simultaneous interconnection to numerous devices using multiple connection types and protocols
COMMUNICATION GATEWAY
Supports multiple gateways perfect for complex installations that involve new or legacy metering devices. Gateways can run simultaneously for robust performance.
Key Specifications:
- Facilitate communication between master and slave devices operating on different protocols
- Connect multiple master and slave devices for simple, facility wide management
- SNMP Gateway - Convert connected Modbus, BACnet and Mbus devices to available SNMP devices, designed for data center management systems
- Modbus Gateway - All RTU devices can be polled by Modbus TCP/IP devices.
- BACnet Gateway - Convert Modbus-RTU (RS485) to BACnet-IP
- Ethernet Gateway - Modbus-RTU (RS485) and digital output devices
DATA POST
The AcuLink 810 can automatically post data to an external system for storage or processing.
Key Specifications:
- Push critical facility data to a web-based energy management system or front-end software platform
- Send data in CSV or JSON file format to external HTTP/HTTPs or FTP/FTPs servers
8GB RAPID DATA LOGGER
Leading 8GB internal storage with blistering fast rapid logger option provides accurate data acquisition collection for critical systems that demand real-time response.
Key Specifications:
- 8GB internal memory for storing critical consumption data
- High-speed data logging records time-stamped data at 1-second intervals
- Large capacity local storage to backup data continuous
- Three internal data loggers can be independently configured for different recording intervals or file formats
- Logged data can be downloaded or pushed to remote servers
COMMUNICATION INTERFACE
The AcuLink 810 is designed to be a complete network solution that supports multiple communication options.
Key Specifications:
- WiFi
- RS485
- Mesh Communications
- Dual Ethernet for IP-based Connections: Connect up to 32 devices via RSTP
- USB 2.0 Port: Connect an additional 32 Modbus-RTU devices daisy chaining via USB-to-RS485 adapter
EMBEDDED WEB SERVER
The AcuLink 810 features a web interface that can be access remotely or locally for 24/7 data access anytime, anywhere.
Key Specifications:
- Use Ethernet, WiFi, or the Internet to view real-time data, historical logs, or configuration information for all connected field devices
- View measurements, summaries, and alarm conditions through any web browser
- Compliant with SSL and TLS 1.2 for enhanced cybersecurity
Data Acquisition |
---|
DATA ACQUISITION (DAQ)
AcuLink 810 can gather data from any Accuenergy or third-party meters, sensors, or other field devices for a seamless network under one centralize hub and supports a large number of standard protocols.
Key Specifications:
- Multiple connection methods including Ethernet, WiFi, RS485, & wireless Mesh
- Support for standard industrial protocols: Modbus-RTU, Modbus TCP/IP, BACnet MT/TP, BACnet-IP, MBus, Virtual Meters and more
- Simultaneous interconnection to numerous devices using multiple connection types and protocols
Communication Gateway |
---|
COMMUNICATION GATEWAY
Supports multiple gateways perfect for complex installations that involve new or legacy metering devices. Gateways can run simultaneously for robust performance.
Key Specifications:
- Facilitate communication between master and slave devices operating on different protocols
- Connect multiple master and slave devices for simple, facility wide management
- SNMP Gateway - Convert connected Modbus, BACnet and Mbus devices to available SNMP devices, designed for data center management systems
- Modbus Gateway - All RTU devices can be polled by Modbus TCP/IP devices.
- BACnet Gateway - Convert Modbus-RTU (RS485) to BACnet-IP
- Ethernet Gateway - Modbus-RTU (RS485) and digital output devices
Data Post |
---|
DATA POST
The AcuLink 810 can automatically post data to an external system for storage or processing.
Key Specifications:
- Push critical facility data to a web-based energy management system or front-end software platform
- Send data in CSV or JSON file format to external HTTP/HTTPs or FTP/FTPs servers
Data Logging |
---|
8GB RAPID DATA LOGGER
Leading 8GB internal storage with blistering fast rapid logger option provides accurate data acquisition collection for critical systems that demand real-time response.
Key Specifications:
- 8GB internal memory for storing critical consumption data
- High-speed data logging records time-stamped data at 1-second intervals
- Large capacity local storage to backup data continuous
- Three internal data loggers can be independently configured for different recording intervals or file formats
- Logged data can be downloaded or pushed to remote servers
Communication Interface |
---|
COMMUNICATION INTERFACE
The AcuLink 810 is designed to be a complete network solution that supports multiple communication options.
Key Specifications:
- WiFi
- RS485
- Mesh Communications
- Dual Ethernet for IP-based Connections: Connect up to 32 devices via RSTP
- USB 2.0 Port: Connect an additional 32 Modbus-RTU devices daisy chaining via USB-to-RS485 adapter
Embedded Web Server |
---|
EMBEDDED WEB SERVER
The AcuLink 810 features a web interface that can be access remotely or locally for 24/7 data access anytime, anywhere.
Key Specifications:
- Use Ethernet, WiFi, or the Internet to view real-time data, historical logs, or configuration information for all connected field devices
- View measurements, summaries, and alarm conditions through any web browser
- Compliant with SSL and TLS 1.2 for enhanced cybersecurity
Data
Acquisition
Communication
Gateway
Data
Post
Data
Logging
Communication
Interface
Embedded
Web Server
AcuLink 810 Network Architecture
AcuLink 810 Product Map
1 | Dual Ethernet PortsDaisy chain up to 32 devices using RSTP | 7 | Digital Inputs 1-4Each can be used as an input pulse counter |
2 | USB 2.0 PortConnection for a RS485 to USB converter for up to 32 more device connections | 8 | Digital Inputs 5-8Each can be used as an input pulse counter |
3 | WiFi & AcuMesh AntennasRequired for WiFi and Mesh communications (if equipped) | 9 | RS485 ConnectionRS485 Modbus supports up to 32 devices (expandable) |
4 | AcuMesh Status LEDsIndicates signal strength & transceiver status (if equipped) | 10 | Power ConnectionRated for 24Vdc |
5 | WiFi Status LEDsIndicates access point mode, station mode, & proper functioning | 11 | Wall MountingBuilt-in keyhole hangers |
6 | RS485 Status LEDsIndicates communication status | 12 | DIN Rail MountingCompatible with horizontal TS35 DIN rail |
1 | Dual Ethernet PortsDaisy chain up to 32 devices using RSTP |
2 | USB 2.0 PortConnection for a RS485 to USB converter for up to 32 more device connections |
3 | WiFi & AcuMesh AntennasRequired for WiFi and Mesh communications (if equipped) |
4 | AcuMesh Status LEDsIndicates signal strength & transceiver status (if equipped) |
5 | WiFi Status LEDsIndicates access point mode, station mode, & proper functioning |
6 | RS485 Status LEDsIndicates communication status |
7 | Digital Inputs 1-4Each can be used as an input pulse counter |
8 | Digital Inputs 5-8Each can be used as an input pulse counter |
9 | RS485 ConnectionRS485 Modbus supports up to 32 devices (expandable) |
10 | Power ConnectionRated for 24Vdc |
11 | Wall MountingBuilt-in keyhole hangers |
12 | DIN Rail MountingCompatible with horizontal TS35 DIN rail |
AcuLink 810 Models
AcuLink 810-X | AcuLink 810-900 | AcuLink 810-868 | |
---|---|---|---|
AcuMesh | N/A | AcuMesh: 900MHz | AcuMesh: 868MHz |
Incoming Protocols | Modbus-RTU, Modbus-TCP/IP, BACnet-MS/TP, BACnet-IP, SunSpec, Mbus, Pulse Counter, Virtual Meters | ||
Outgoing Protocols | Modbus-TCP/IP, BACnet-IP, SNMP, HTTP/HTTPs, FTP/sFTP, MQTT | ||
Memory | 8GB RAM | ||
Recording Intervals | 1 to 1440 minutes (24 hours); user selectable | ||
Ethernet | Dual RJ45 10/100 Ethernet Ports | ||
WiFi | 902.11 b/g/n, 2.4GHz | ||
Digital Inputs | 8 pulse counters | ||
RS485 Port | RS485 Modbus; supports up to 32 external devices (expandable) | ||
USB Port | Modbus via RS485-to-USB converter; supports up to 32 external devices | ||
Baud Rate | 9600-115200 bps | ||
Mounting | DIN rail or wall mount |
AcuLink 810-X |
---|
AcuMesh | N/A |
---|---|
Incoming Protocols | Modbus-RTU, Modbus-TCP/IP, BACnet-MS/TP, BACnet-IP, SunSpec, Mbus, Pulse Counter, Virtual Meters |
Outgoing Protocols | Modbus-TCP/IP, BACnet-IP, SNMP, HTTP/HTTPs, FTP/sFTP, MQTT |
Memory | 8GB RAM |
Recording Intervals | 1 to 1440 minutes (24 hours); user selectable |
Ethernet | Dual RJ45 10/100 Ethernet Ports |
WiFi | 902.11 b/g/n, 2.4GHz |
Digital Inputs | 8 pulse counters |
RS485 Port | RS485 Modbus; supports up to 32 external devices (expandable) |
USB Port | Modbus via RS485-to-USB converter; supports up to 32 external devices |
Baud Rate | 9600-115200 bps |
Mounting | DIN rail or wall mount |
AcuLink 810-900 |
---|
AcuMesh | AcuMesh: 900MHz |
---|---|
Incoming Protocols | Modbus-RTU, Modbus-TCP/IP, BACnet-MS/TP, BACnet-IP, SunSpec, Mbus, Pulse Counter, Virtual Meters |
Outgoing Protocols | Modbus-TCP/IP, BACnet-IP, SNMP, HTTP/HTTPs, FTP/sFTP, MQTT |
Memory | 8GB RAM |
Recording Intervals | 1 to 1440 minutes (24 hours); user selectable |
Ethernet | Dual RJ45 10/100 Ethernet Ports |
WiFi | 902.11 b/g/n, 2.4GHz |
Digital Inputs | 8 pulse counters |
RS485 Port | RS485 Modbus; supports up to 32 external devices (expandable) |
USB Port | Modbus via RS485-to-USB converter; supports up to 32 external devices |
Baud Rate | 9600-115200 bps |
Mounting | DIN rail or wall mount |
AcuLink 810-868 |
---|
AcuMesh | AcuMesh: 868MHz |
---|---|
Incoming Protocols | Modbus-RTU, Modbus-TCP/IP, BACnet-MS/TP, BACnet-IP, SunSpec, Mbus, Pulse Counter, Virtual Meters |
Outgoing Protocols | Modbus-TCP/IP, BACnet-IP, SNMP, HTTP/HTTPs, FTP/sFTP, MQTT |
Memory | 8GB RAM |
Recording Intervals | 1 to 1440 minutes (24 hours); user selectable |
Ethernet | Dual RJ45 10/100 Ethernet Ports |
WiFi | 902.11 b/g/n, 2.4GHz |
Digital Inputs | 8 pulse counters |
RS485 Port | RS485 Modbus; supports up to 32 external devices (expandable) |
USB Port | Modbus via RS485-to-USB converter; supports up to 32 external devices |
Baud Rate | 9600-115200 bps |
Mounting | DIN rail or wall mount |
AcuLink 810 Accessories
AcuLink 810 Power Supply
AcuLink-RIK-PSU Class 2 100-240Vac to 24Vdc power supply has a DIN rail design for mounting next to the AcuLink 810.
RS485-to-USB Converter
This plug-and-play USB to Serial RS485 Converter is designed to provide a convenient, reliable USB connection to the AcuLink 810.
Magnetic Mount Antenna
AcuLink 810-900 and AcuLink 810-868 models supports a 2db Magnetic Mount Antenna with 3 meter extension cable to maximize reception. Magnetic mounting is ideal for securing to metal cabinets.